Medical clean South China Sea clean room design project

The medical clean South China Sea clean room design project is an interdisciplinary subject that touches on multiple disciplines. It uses air conditioning technology, physical filtration, airflow organization, differential pressure control and other technical means to control pollution particles to control microbial contamination, and then control the environment. The policy establishes a comprehensive security system.
Medical clean South China Sea clean room design project

The medical clean South China Sea clean room design project is an interdisciplinary subject that touches on multiple disciplines. It uses air conditioning technology, physical filtration, airflow organization, differential pressure control and other technical means to control pollution particles to control microbial contamination, and then control the environment. The policy establishes a comprehensive security system. The medical clean South China Sea clean room design project should play its due role in the medical and health profession. It is necessary to cooperate with many disciplines such as architecture, medicine, economics, psychology, modern management, and modern information science.

In the planning and design stage of the project, we must be clear that in the process of construction and application of our project, we need to use the medical clean South China Sea clean room design technology, and in what areas we need to use the medical clean South China Sea clean room design technology.

Medical clean South China Sea clean room design project in the medical profession to solve the problem

1. Control pollution and disperse

Firstly, in bio-safety laboratories and air-conducted epidemic barrier wards, as microbial environmental pollution, one is through microscopic humans and things as carriers, and the other is through microscopic carriers and their own dispersal. The pollution scatter through the microscopic human and material as the carrier is mainly controlled by the disinfection method and the handling method. The microscopic carrier and the microbial contamination can be controlled by the medical clean South China Sea clean room design technology.

2, control infection

The hospital purification project is mainly in the clean room operating room, to prevent infected wards (ICU, PICU, severe burn patients, severe respiratory diseases, leukemia patients receiving chemotherapy, wards of patients with leukopenia malignant tumors), and sterile wards. The infection of the personnel is divided into endogenous infection and exogenous infection. Endogenous infection belongs to the medical professional scale. The path of exogenous infection is divided into touch, body fluid and air. We control by reducing the concentration of microorganisms in individual surrounding environment. The chance of exogenous infections can be very well controlled using an excellent airflow tissue distribution.

3. Satisfied personnel and equipment for environmental pleading

Medical Nanhai clean room design purification through the setting of outstanding environmental parameters, to meet the environmental requirements of the personnel working in the environment and the equipment used, such as clean room, humidity, temperature, fresh air volume, noise, pressure difference.

In the medical profession, there is a pair of hostile, biological barrier and pollution control compared to the medical clean South China Sea clean room design technology. The biological barrier is to protect the personnel and the environment from harmful substances. The pollution control is to prevent the maintenance policy from being Human, biological, environmental pollution. In the biosafety laboratory, it is necessary to be consistent with this pair of enemies, and then increase the difficulty of the corresponding operations.









Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn

Non-contact Body Infrared Thermometer


Power voltage : D.C. 1.5V 1*LR41 button battery
A unit of temperature : Celsius (℃)
The display range is not narrower than 35.0℃-41.0℃
Bian force 0.1 ℃ or less
Measurement time < 60s (thermostatic water tank)
The memory function : records the last measurement
Maximum allowable error:


Maximum permissible error of temperature display range
< 35.3 ℃ plus or minus 0.3 ℃
35.3 ℃ to 36.9 ℃ plus or minus 0.2 ℃
37.0 ℃ to 39.0 ℃ plus or minus 0.1 ℃
39.1 ℃ to 41.0 ℃ plus or minus 0.2 ℃
> 41 ℃ plus or minus 0.3 ℃
Operating environment temperature : 10℃ ~ 40℃;Relative humidity: ≤80%RH
Storage environment temperature : -20℃ ~ 55℃;Relative humidity: ≤93%RH


Thermometer

Thermometer

Thermometer

Oral Glass Thermometer,Glass Thermometer,Digital Thermometer ,Infrared Thermometer

Zhongshan Saifute Labor Protective Articles Co., Ltd , http://www.factorydirectmask.com