000 US A8 gas tank valve installation precautions (Figure)

Large flow gas tank valve, as shown: the implementation of standards; CJ50-2008 license number; XK21-006-00084 JYT-0.6-A8 inlet pressure; 0.03 ~ 1.56MPa outlet pressure; 2.80KPa ~ 0.5kpa million US A8 gas tank pressure relief valve for household use LPG tank. Gas tank valve installation Notes: 1. The valve inlet into the cylinder angle valve interface, turn the hand counterclockwise to the valve should be maintained at a level position, the gas pipe must be inserted into the cordon, out Gap hose application clamp fixed. 2. The product has been adjusted before leaving the outlet flow and pressure, do not arbitrarily adjust. 3. The product should be closed after the cylinder angle valve so that the valve is not in working condition. 4. If the product fails, the user may not disassemble, you should promptly contact the dealer or manufacturer. 5. For the safety of you and others, and the implementation of national compulsory regulations, this product is recommended for safe use of three years to replace their own users, the gas tank pressure relief valve for the 1.2 flow of household gas tank pressure relief valve, the output flow and pressure than General household valve large. Recommended for large flow of home gas water heater or household gas stove use. Recommend fierce fire users like to use.